Operating Instructions
and User’s Information Manual
for use by engineers and heating contractors
5728 556 v1.0 01/2011
Read and save these instructions
for future reference.
Vitotronic 100
Model KW10A
Boiler control unit
for modulating temperature heating systems
Part No. 7453 016
VITOTRONIC 100
Please file in Service Binder
IMPORTANT
Certified as a component
part for Viessmann boilers

Other manuals for Viessmann KW10A

Questions and Answers

  • C
    Carlos DavidsonAug 12, 2025
    What to do if my Viessmann Control Unit boiler is cold and the burner isn't running?
    • A
      Anthony WadeAug 12, 2025
      If your Viessmann Control Unit boiler is cold and the burner isn't running, here are a few things you can check: * The high limit safety cut-out may have responded. In this case, reset the high limit safety cut-out. * There may be a problem with external safety equipment. Check the connection and the external safety equipment itself. * There may be a problem with Vitotrol 100. Check the connection and Vitotrol 100. If necessary, insert a jumper across control unit terminals 9 and 10. * The MCB F1 may have responded. Check the connections and the burner, and replace the fuse if needed. * The burner may be in a fault state. Check the burner.
  • C
    Colton KennedyAug 17, 2025
    What to do if my Viessmann KW10A Control Unit heating circuit pump is not running?
    • D
      davisrandallAug 17, 2025
      If the heating circuit pump on your Viessmann Control Unit is not running, the issue might be related to the Vitotrol 100. Check the connection and the Vitotrol 100. If necessary, insert a jumper across control unit terminals 4 and 5.
  • C
    Cathy JonesAug 25, 2025
    What to do if there is a burner fault in Viessmann KW10A?
    • R
      Ronald BaileyAug 25, 2025
      If you're experiencing a burner fault with your Viessmann Control Unit, you should check the burner.
  • W
    wcarterAug 29, 2025
    What to do if Viessmann Control Unit has an internal fault?
    • C
      Carla StevensAug 29, 2025
      In case of an internal fault in your Viessmann Control Unit, you should check the electronics PCB.
  • D
    Derek HoldenSep 4, 2025
    What to do if Viessmann KW10A Control Unit shows invalid hardware?
    • J
      Jason McgrathSep 4, 2025
      If your Viessmann Control Unit displays an invalid hardware error, check the main PCB.

Viessmann KW10A Specifications

General IconGeneral
CategoryControl Unit
BrandViessmann
ModelKW10A
Power supply230 V AC
Power consumption5 W