VITOTRONIC 100
Operating Instructions
and User’s Information Manual
Vitotronic 100
Model KK10
Boiler control unit
for high temperature heating systems
Part No. 7133 374
Read and save these instructions
for future reference.
IMPORTANT
Certified as a component part
of Viessmann boilers only
5167 482 v1.2 09/2007
Please file in Service Binder

Other manuals for Viessmann KK10

Questions and Answers

  • Q
    qrobinsonAug 12, 2025
    What to do if my Viessmann Control Unit boiler is cold and the burner isn't running?
    • L
      Lisa ChristianAug 12, 2025
      If your Viessmann Control Unit boiler is cold and the burner isn't running, here are a few things you can check: * The high limit safety cut-out may have responded. In this case, reset the high limit safety cut-out. * There may be a problem with external safety equipment. Check the connection and the external safety equipment itself. * There may be a problem with Vitotrol 100. Check the connection and Vitotrol 100. If necessary, insert a jumper across control unit terminals 9 and 10. * The MCB F1 may have responded. Check the connections and the burner, and replace the fuse if needed. * The burner may be in a fault state. Check the burner.
  • J
    Jennifer StewartAug 17, 2025
    What to do if my Viessmann KK10 Control Unit heating circuit pump is not running?
    • Z
      Zachary MooreAug 17, 2025
      If the heating circuit pump on your Viessmann Control Unit is not running, the issue might be related to the Vitotrol 100. Check the connection and the Vitotrol 100. If necessary, insert a jumper across control unit terminals 4 and 5.
  • J
    Joshua TaylorAug 23, 2025
    What to do if there is a burner fault in Viessmann KK10?
    • S
      Suzanne MillerAug 23, 2025
      If you're experiencing a burner fault with your Viessmann Control Unit, you should check the burner.
  • J
    Joy ReynoldsAug 29, 2025
    What to do if Viessmann KK10 Control Unit has an internal fault?
    • P
      patrick88Aug 29, 2025
      In case of an internal fault in your Viessmann Control Unit, you should check the electronics PCB.
  • S
    steven91Sep 5, 2025
    What to do if Viessmann Control Unit shows invalid hardware?
    • L
      Lauren SmallSep 5, 2025
      If your Viessmann Control Unit displays an invalid hardware error, check the main PCB.