16
Cause Remedy
The thermostat has a fault. Turn the thermostatic head for more information about the faults.
flashes.
Cause Remedy
flashes on the thermostat display ap-
proximately 1 month before the batteries run
out.
Replace the batteries: See page 11.
is illuminated continuously.
Cause Remedy
The batteries of the thermostatic radiator
valve have run out.
It can no longer be operated.
Replace the batteries: See page 11.
is displayed.
Cause Remedy
"Open window detection" function is switch-
ed on.
No action required.
If the room temperature rises again within 30 minutes, the func-
tion is automatically switched off.
After 30 minutes, the function is automatically switched off even if
the temperature has not risen.
If you change the current set room temperature, the function is
automatically switched off.
If the room temperature falls below 8 °C, the frost protection
function is activated and the "open window detection" function is
switched off.
and are displayed.
Only in conjunction with a gateway
Cause Remedy
"Open window detection" function is switch-
ed on.
No action required.
If the room temperature rises again within 30 minutes, the func-
tion is automatically switched off.
If you change the current set room temperature, the function is
automatically switched off.
is displayed.
Cause Remedy
Fault in the thermostatic radiator valve mo-
tor
Dismount the thermostatic radiator valve: See page 20.
Remove the batteries and reinsert them: See page 11.
Replace the thermostatic radiator valve if necessary.