19
Power supply 2 x 1.5 V alkaline batteries LR6, type AA
Note
Do not use rechargeable batteries.
Battery life Approx. 2 years
Noise level < 30 dB(A) at a distance of 1 m
Radio frequency 2.4 GHz Zigbee 3.0 wireless standard
Frequency band 2405.0 to 2480.0 MHz
Max. transmitting power 0.1 W (e.i.r.p.)
Transmission interval Every 7.5 s
Protection class III
IP rating IP 20D to EN 60529; ensure through design/installation.
Normal range +8 to +30 °C
Rated lift range 4.2 mm
Valve control force 70 N
Connection M 30 x 1.5
Adaptor for Danfoss RAV, RA, RAVL included in standard delivery
Permissible ambient temperature
■
Operation 0 to +40 °C
Installation in living spaces or boiler rooms (standard ambient con-
ditions)
■
Storage and transport –20 to +60 °C
Specification
Specification
6155182