Requirements for the installation room
!
Please note
Unfavourable ambient conditions can lead to
malfunctions and appliance damage.
The installation room must be dry and free
from the risk of frost.
Ensure ambient temperatures between 0 and
35 °C.
Max. 70 % relative humidity (corresponds to
an absolute humidity of approx. 25 g water
vapour/kg dry air)
Danger
Dust, gases and vapours can be damaging to
health and trigger explosions.
Avoid dust, gases and vapours in the installation
room.
!
Please note
Overloading the floor can result in damage to
the building structure.
Observe the permissible floor load. Take
account of the total weight of the appliance: See
chapter "Pressure points".
Minimum clearances
Secondary circuit connections, left/top
1000
250
Fig. 15
Secondary circuit connections, right/top
1000
250
Fig. 16
Installation sequence
Installing the indoor unit (cont.)