Installation and service
instructions
for contractors
VIESMANN
Vitodens 050-W
Type BPJD, 6.5 to 35.0 kW
Wall mounted gas condensing boiler
For natural gas and LPG
Gas Council Number: 47 819 31, 47 819 32
For applicability, see the last page
VITODENS 050-W
5675 991 GB 2/2015
Please keep safe.

Table of Contents

Questions and Answers

  • A
    Ashley NicholsAug 17, 2025
    How to fix no increase set value on Viessmann Boiler?
    • O
      onealsamanthaAug 17, 2025
      To address the issue of no increase in the set value on your Viessmann Boiler, increase the set value and ensure that heat is being drawn off. The cause of this problem might be control unit issues.
  • D
    Daniel HernandezAug 19, 2025
    What to do if my Viessmann Vitodens 050-W BP JD Boiler burner stops below the set water temperature and restarts immediately?
    • Z
      zschmidtAug 20, 2025
      If the burner stops below the set boiler water temperature and restarts immediately, check the flue system for tightness to prevent flue gas recirculation. Also, check the gas flow pressure.
  • K
    Katherine Lee DDSAug 22, 2025
    What to do if my Viessmann Vitodens 050-W BP JD displays fault code 52?
    • H
      Hannah GarciaAug 22, 2025
      If fault code 52 is displayed, which indicates a short circuit in the flow sensor, check the connections and lead. If necessary, replace the sensor.
  • W
    William WilcoxAug 25, 2025
    What to do if my Viessmann Boiler displays fault code 51?
    • W
      wileymicheleAug 26, 2025
      If your Viessmann Boiler displays fault code 51, indicating a short circuit in the outlet temperature sensor, check the sensor.
  • D
    David BaileyAug 27, 2025
    What to do if my Viessmann Vitodens 050-W BP JD Boiler displays fault code 38?
    • O
      oedwardsAug 28, 2025
      If fault code 38 is displayed on your Viessmann Boiler, it indicates a lead break in the boiler water temperature sensor. Check the boiler water temperature sensor.
  • S
    Shane DrakeAug 30, 2025
    What to do if my Viessmann Vitodens 050-W BP JD Boiler displays fault code 30?
    • R
      reyeskristyAug 31, 2025
      If your Viessmann Boiler shows fault code 30, which means there's a short circuit in the boiler water temperature sensor, check the boiler water temperature sensor.
  • M
    Mrs. Diana CollinsSep 2, 2025
    What to do if my Viessmann Vitodens 050-W BP JD Boiler displays fault code 18?
    • B
      Bailey ZamoraSep 2, 2025
      If your Viessmann Boiler displays fault code 18, which indicates a lead break in the outside temperature sensor, check the outside temperature sensor and lead.
  • B
    Brian BerrySep 5, 2025
    What to do if my Viessmann Vitodens 050-W BP JD displays fault code 10?
    • J
      Jessica BoothSep 5, 2025
      If your Viessmann Boiler displays fault code 10, indicating a short circuit in the outside temperature sensor, check the outside temperature sensor and lead.
  • T
    Tyrone WeissSep 8, 2025
    What to do if my Viessmann Boiler displays fault F4 due to gas train issues?
    • A
      Anthony PittsSep 8, 2025
      If your Viessmann Boiler displays fault F4 and the cause is related to the gas train opening, check the gas train for the correct control voltage (230 V) and verify the gas supply pressure.
  • A
    Andres AguilarSep 10, 2025
    What to do if my Viessmann Vitodens 050-W BP JD Boiler displays fault F4 related to ignition?
    • J
      Jonathan SmithSep 12, 2025
      If your Viessmann Boiler displays fault F4, and it's related to ignition, check the ignition module connection.

Summary

Safety Instructions

Safety Symbols and Explanations

Explains safety symbols like Danger, Please note, and Note.

Safety Instructions (cont.)

Repair Work Guidelines

Provides guidance on performing repairs on the appliance components.

Water Escape Safety

Safety steps to take when water leaks from the appliance.

Flue Systems and Combustion Air Safety

Ensuring proper function and safety of flue systems and air supply.

Gas Leak Safety

Instructions on what to do if gas is detected.

Flue Gas Leak Safety

Instructions on what to do if flue gas is detected.

Information (cont.)

Preparing for Installation

Preparing for Installation (cont.)

Installation Sequence

Mounting the Boiler and Connections

Steps for mounting the boiler and connecting it.

Installation Sequence (cont.)

Water Side Connections

Detailed steps for connecting the water lines.

Gas Connection

Procedure for connecting the gas supply.

Electrical Connections

Wiring instructions for electrical connections.

Installation Sequence (cont.)

Installation Sequence (cont.)

Power Supply Connection

Connecting the appliance to the power supply.

Commissioning, Inspection, Maintenance

Steps: Commissioning, Inspection, Maintenance

Overview of the steps for commissioning, inspection, and maintenance.

Commissioning, Inspection, Maintenance (cont.)

Checking Supply (Flow) Pressure

How to check the gas supply (flow) pressure.

Burner Removal

Step-by-step guide to removing the burner.

Gas Connections Leak Check

Procedure for checking gas connections for leaks.

Filling the Heating System

Step-by-step guide to filling the heating system.

Checking Static and Supply Pressure

How to check static and supply gas pressure.

Expansion Vessel and System Pressure Check

How to check the expansion vessel and system pressure.

Gas Equipment Tightness Check

Checking gas equipment tightness during operation.

Commissioning, Inspection, Maintenance (cont.)

Commissioning, Inspection, Maintenance (cont.)

Commissioning, Inspection, Maintenance (cont.)

Checking the CO2 Content

Procedure for measuring and checking CO2 levels.

Setting Heating Output and CO2 Check

Adjusting heating output and verifying CO2 content.

Electrode Check and Adjustment

Procedure for checking and adjusting the electrode gap.

Cleaning the Heat Exchanger

Instructions for cleaning the heat exchanger.

Condensate Drain and Siphon Check

How to check and clean the condensate drain and siphon.

Installing the Burner

Step-by-step guide to installing the burner.

Troubleshooting

Function Sequence and Possible Faults

Flowchart showing operational sequence and potential faults.

Troubleshooting (cont.)

Fault Display Overview

Explanation of fault codes and display indicators.

Fault Code Explanations and Measures

Detailed explanation of fault codes and corresponding troubleshooting measures.

Troubleshooting (cont.)

Repairs

Removing the Front Panel

Steps for removing the front panel for repair access.

Repairs (cont.)

Outside Temperature Sensor Check

Procedure for checking the outside temperature sensor.

Boiler Water Temperature Sensor Check

Procedure for checking the boiler water temperature sensor.

Outlet Temperature Sensor Check

Procedure for checking the outlet temperature sensor.

Flue Gas Temperature Sensor Check

Procedure for checking the flue gas temperature sensor.

Repairs (cont.)

Checking the Temperature Limiter

Procedure for checking the temperature limiter.

Repairs (cont.)

Gas Type Conversion

Gas Type Conversion (cont.)

Control Unit

Control Unit (cont.)

Designs

Designs (cont.)

Specification

Certificates

Viessmann Vitodens 050-W BP JD Specifications

General IconGeneral
ModelVitodens 050-W BP JD
CategoryBoiler
TypeWall-mounted gas condensing boiler
Energy Efficiency ClassA
Flue Gas Connection60/100 mm
Power Supply230 V / 50 Hz
Heat Exchanger MaterialStainless steel
Water Pressure (max)3 bar
Fuel TypeNatural Gas / LPG
Water Temperature Range30°C to 80°C

Related product manuals