08. OK to confirm
Further information regarding the message is dis-
played.
09. Make a note of the service message number. For
example: P.1 "Interval until the next service".
This enables the contractor to be better prepared
and may save you unnecessary travelling costs.
10. Please notify your heating contractor.
Note
If the service cannot be carried out until a later
date, the service message will be displayed again
the following Monday.
11. for approx. 3 s, to exit the menu.
Checking fault messages
If your system has developed faults, "Burner fault" or
"Active messages" are displayed. The Lightguide is
flashing: See chapter "Switching the Lightguide on and
off".
Danger
If faults are not rectified, they can have life
threatening consequences.
Do not acknowledge fault messages several
times in quick succession. Please notify your
contractor if a fault occurs. Your contractor will
be able to analyse the cause and rectify the
fault.
Note
If you have connected a message facility to alert you
to fault messages (e.g. a buzzer), this is deactivated
when the fault message is acknowledged.
If troubleshooting cannot be carried out until a later
date, the fault message will be displayed again the
following day at 07:00. The message facility is
switched on again.
Burner fault
Shown on display: "The burner control unit is locked out"
Tap the following buttons:
01. for "Ignore"
02. OK to confirm
The burner remains locked out.
03. OK to acknowledge the information
04. press and hold for approx. 3 s.
05. press and hold for approx. 3 s.
06. for "Active messages"
07. OK to confirm
08. for "Faults"
09. OK to confirm
10. for the required message
11. OK to confirm
Further information regarding the message is dis-
played.
12. Make a note of the fault number.
This enables the contractor to be better prepared
and may save you unnecessary travelling costs.
13. Please notify your heating contractor.
14. for approx. 3 s, to exit the menu.
Faults without burner fault
Tap the following buttons:
01. OK to confirm
02. press and hold for approx. 3 s.
03. press and hold for approx. 3 s.
04. for "Active messages"
05. OK to confirm
06. for "Error message"
07. OK to confirm
08. for the required message
Checks
Checking service messages (cont.)
6172108

Table of Contents

Other manuals for Viessmann Vitodens 222-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitodens 222-F and is the answer not in the manual?

Viessmann Vitodens 222-F Specifications

General IconGeneral
TypeGas Condensing Boiler
ModelVitodens 222-F
Integrated DHW Storage TankYes
ControlVitotronic 200
Fuel TypeNatural Gas or LPG
Heat Exchanger MaterialStainless Steel
Modulation Range1:10
Max. Water Temperature85°C
EfficiencyUp to 98%
Tank Capacity130 liters
DHW Tank Capacity130 liters
Installation TypeFloor Standing
Water PressureUp to 3 bar
Noise LevelDependent on model and operating conditions (typically around 40-50 dB(A))