16. EMC (ELECTROMAGNETIC COMPATIBILITY) Information
The Electromagnetic Compatibility Directive sets the essential requirements for electrical and
electronic equipment that may disturb or even be disturbed by other equipment. The ACP-900 complies
with these requirements as tabled below. Follow the guidance on the tables for use of the
device in the electromagnetic environment.
ACP-900 is suitable for the home healthcare environment.
Warning for EMC
Minimum distance from RF
communications
Portable RF communications equipment (including peripherals such
as antenna cables and external antennas) should be used no closer
than 30 cm (12 inches) to any part of the ACP-900, including cables
specified by the UNICOS.
Otherwise, degradation of the performance of this equipment could
result.”
EMC Information
Phenomenon
B
asic EMC
s
tandard or test
m
ethod
O
perating
m
ode
P
ort
t
ested
T
est Voltage
T
est
l
eve/requirement
Mains terminal
disturbance
voltage
CISPR11:2015 Image display
AC Mains
120 V, 60 Hz
220 V, 60 Hz
230 V, 50 Hz
Group1, Class A
Radiated
disturbance
CISPR11:2015 Image display
Enclosure
120 V, 60 Hz
220 V, 60 Hz
230 V, 50 Hz
Group1, Class A
Harmonic Current
Emission
IEC
61000-3-2:2014
Image display
AC Mains
230 V, 50 Hz Class A
Voltage change,
Voltage
fluctuations and
Flicker Emission
IEC
61000-3-3:2013
Image display
AC Mains
230 V, 50 Hz
Pst: 1
Plt: 0.65
Tmax:0.5
dmax: 4%
dc: 3.3%
Electrostatic
Discharge
Immunity
IEC
61000-4-2:2008
Image display
Stand by
Enclosure
120 V, 60 Hz
220 V, 60 Hz
230 V, 50 Hz
± 8 kV/Contact
± 2, ± 4, ± 8,
± 15 kV/Air
Radiated RF
Electromagnetic
Field Immunity
IEC
61000-4-3:2006
/AMD2:2010
Image display
Stand by
Enclosure
120 V, 60 Hz
220 V, 60 Hz
230 V, 50 Hz
3 V/m
80 MHz-2.7 GHz
80% AM at 1 kHz
Immunity to
Proximity Fields
from RF wireless
Communications
Equipment
IEC
61000-4-3:2006
/AMD2:2010
Image display
Stand by
Enclosure
120 V, 60 Hz
220 V, 60 Hz
230 V, 50 Hz
Table 9 in
IEC 60601-1-2:
2014
Electrical Fast
Transient/Burst
Immunity
IEC
61000-4-4:2012
Image display
Stand by
Image display
Stand by
AC Mains
120 V, 60 Hz
220 V, 60 Hz
230 V, 50 Hz
120 V, 60 Hz
220 V, 60 Hz
230 V, 50 Hz
± 2 kV, 100 kHz
repetition
frequency
Surge Immunity
IEC
61000-4-5:2014
Image display
Stand by
Image display
Stand by
AC Mains
120 V, 60 Hz
220 V, 60 Hz
230 V, 50 Hz
120 V, 60 Hz
220 V, 60 Hz
Line to Line
± 0.5 kV, ± 1 kV
Line to Ground
± 0.5 kV, ± 1 kV, ±