EasyManua.ls Logo

ViewSonic CD4233 - Get-Function Listing

ViewSonic CD4233
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commercial Display RS-232 Protocol
Revision 1.x
________________________________________________________________
May 28, 2007 12 / 16 Commercial Display RS-232 Protocol
004 : YPbPr
005 : S-Video
Monitor ID
5
=
3D
001 ~ 026
Number
5
@
40
000 ~ 009
Key Pad
5
A
41
000 : POWER
001 : SOURCE
002 : MENU/EXIT
003 : UP
004 : DOWN
005 : LEFT
006 : RIGHT
007 : MUTE
Remote Control
5
B
42
000: Disable
Disable: RCU has no effect on
HDTV.
001: Enable
Enabled: RCU controls the
HDTV. This is the power up
default on the HDTV.
002: Pass through
Pass through: RCU has no
effect on HDTV and all RCU
command codes are transmitted
to FC via the RS232 port. See
page 26 for more details
Key Pad
5
C
43
000: Disable
Disable: Key Pad have no
effect on HDTV.
001: Enable
Enabled: Key Pad control the
HDTV. This is the power up
default on the HDTV.
Factory reset
5
~
7E
0
Rests HDTV to factory setting
4.2
Get-Function Listing
The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format
consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte
is always = 00.
Get-Function description:
Total bytes of message = 5 ASCII (35H), excluding “CR”
Get-Function command code: One byte ASCII code
Always = 000
Get-Function format from PC to LCD (ASCII)
Name
Length
Command
Value1
Value2
Value3
CR
Byte Count
5
1 Byte
0
0
0
00D
Bytes order
1
2
3
4
5
6
Monitor shall response to Get-Function with the following packet format:
LCD Monitor response packet format:
Name
Length
Value1
Value2
Value3
Value4
CR