Other Information
40
Reply (Hex Format)
Name Length ID Command
Type
CR
Hex
0x34 0x30
0x35
0x2D 0x0D
Get-function table
Get
Function
Length ID Command
Type
Command Response Range
(Three ASCII
bytes)
Comments
Code (ASCII) Code (Hex)
Get-Contrast 8 g a 61 000 ~ 100
Get-Brightness 8 g b 62 000 ~ 100
Get-Sharpness 8 g c 63 000 ~ 100
Get-Color 8 g d 64 000 ~ 100
Get-Tint 8 g e 65 000 ~ 100
Get-Volume 8 g f 66 000 ~ 100
Get-Mute 8 g g 67 000: Off
001: On (muted)
Get-Input select 8 g j 6A 000~ See Set-function
table
Get-Power
status: ON/
STBY
8 g l 6C 001: ON
000: STBY
Get-Remote
control
8 g n 6E 000: Disable
001: Enable
002: Pass
through
Gets RCU mode
status
Get-Power lock 8 g o 6F 000: Unlock
001: Lock
Get-Button lock 8 g p 70 000: Unlock
001: Lock
Get-Menu lock 8 g q 71 000: Unlock
001: Lock
Get-Setup
wizard
8 g s 73 000: Disable
001: Enable
Get-ACK 8 g z 7A 000 This command is
used
to test the
communication link.
3.3 Remote Control Pass-through mode
When PC sets the TV monitor to Remote Control Pass through mode, the TV shall send a 7 bytes
packet (followed by “CR”) in response to RCU button activation. Note, that in this mode the RCU
shall have no effect on the TV function. For example: “Volume+” will not change the volume in the
LCD but only sends “Volume+” code to PC over the RS232 port.