Viking
Technical
Information
-
Refrigerator
VCSB5481#
FDSB5481#
'
I^EKST"-
"^
°r
Pr°Perty
dam^e.always
contact
an
authorized
technician
for
servicing
or
Refer
to
Service
Manual
for
design,
disassembly,
ice
maker,
safety,
testing
and
troubleshooting
information.
WARNINGS
SHnVp°^neCtriCal
Sh°Ck'
Whi'h
Can
C3USe
S6Vere
personal
irW
or
death.disconnect
power
to
refrigerator
using
power
swttch
before
servicing.
Wires
removed
during
disassembly
must
be
re
placed
on
proper
terminals
to
insure
correct
earthing
and
polarization.
After
servicing
reconnect
power
using
power
switch.
a lcl'ullne"
DC
COMPRESSOR
-
DO
NOT
CONNECT
TO
120
VAC
->-;-'\
Diagnostic
|W
j <"\ j
LED
W»Nj
LOU
GENERAL
SPECIFICATIONS
Model
VCSB5481#
FDSB5481#
Internal Volume
Capacity
27.5
ft A 3
Electrical
Requirements
115
VAC,60Hz
and
9.9
AMPS
Refrigerant
Type
HFC-134a
Refrigerant
Charge
See
Rating
Label
Overall Width (Includes Extrusions)
48
inches
Overall
Depth
without
Handle (Includes DoorExtrusions)
24
inches
Overall Height (Rollers to top of air grille)
82
3/4
to
84
1/16
inches
RETURN
TECHNICAL SHEET TO ENVELOPE AFTER SERVICE
Question and Answer IconNeed help?

Do you have a question about the Viking VCSB5481 Series and is the answer not in the manual?

Viking VCSB5481 Series Specifications

General IconGeneral
BrandViking
ModelVCSB5481 Series
CategoryRefrigerator
LanguageEnglish

Summary

Safety and Warnings

Servicing Safety Precautions

To avoid electrical shock, disconnect power before servicing. Ensure correct earthing and polarization.

DC Compressor Information

Electrical Safety Warning

Do not connect the DC compressor to 120 VAC.

Electronic Functional Description

Power Disconnect Switch

Describes the location and use of the power disconnect switch for servicing.

Alarms

Power Loss and Door Open Alarms

Details Power Loss and Door Open alarm conditions, indicators, and silencing methods.

Temperature and Thermistor Alarms

Covers High Temperature and Thermistor Alarms, including causes and indicators.

Program Mode

Accessing and Options in Mode A

How to enter Program Mode A and details of its adjustable parameters.

Program Mode C

Model Type Configuration

Procedure for changing model type, which sets default operational parameters.

Special Operating Modes

Testing Modes

Details Forced Defrost and Forced Pull-Down (Compressor Start) testing procedures.

Wiring Diagrams

High Voltage Harness and Power Board

Diagram showing high voltage connections and the power board layout.

High Voltage Board Test Points

Inverter Diagnostic Codes

VCC3 Inverter Fault Codes

Details diagnostic codes (flashes) for the VCC3 inverter and corresponding service actions.

Icemaker Operation and Testing

Icemaker Specifications and Checks

Icemaker Troubleshooting

Related product manuals