25
button on, then o, then wait about 1 second and turn on again.
A dierent color option will appear*. e LED light will turn o
automatically after 1 hour.
Color options:
Each time the light is turned on and o it will advance according
to the following sequence:
1. Color wheel: Color changes quickly through available
solid colors.
2. Color fade: Colors fade through spectrum A colors.
3. Random Color Change: Random color changes occur in
quick succession.
4. Spectrum fade: Colors fade through spectrum B colors.
5. Solid Color: Red
6. Solid Color: Green
7. Solid Color: Blue
8. Solid Color: Yellow
9. Solid Color: Indigo
10. Solid Color: Orange
11. Solid Color: Violet
12. Solid Color: White
Preset Filter Cycles
ere are two lter cycles per day. e rst lter cycle begins 6
minutes after the spa is powered up. e second lter cycle begins
12 hours after the start of the rst cycle.
e ltration pump will run during ltration cycles. If you spa
is equipped with more than one pump, the additional pumps
will run for the rst few minutes of each lter cycle to purge
the plumbing. e factory lter cycle duration is 2 hours. Filter
duration can be set to 2,4, 6, or 8 hours. Continuous ltration can
also be selected (indicated by “FC”).
To program lter duration, press Temp” + “Jets 1.” Press “Temp”
to adjust*. Press “Jets 1” to exit programming. *F2= 2 hour
ltration, twice per day, F4= 4 hour ltration, twice per day, Etc.
NOTE: Allowing the lter pump to operate for extended
periods of time with the cover on the spa will result in a rise of
the spa water temperature. During warmer months of the year,
it is advisable to set the duration of the ltration cycle to the
minimum level needed to keep the water clean.
Freeze Protection
If the temperature drops to 44°F (7°C) within the heater, the
pump(s) automatically activates to provide freeze protection. e
pump will stay on 4 minutes after the sensor has detected the
temperature has reached 45°F (7°C) or higher.
Ozone Purier
e optional ozone purier runs during lter cycles and whenever
the spa is heating.
2016 V&B Owners Manual.indd 25 3/3/2016 1:46:25 PM

Other manuals for Villeroy & Boch R6L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Villeroy & Boch R6L and is the answer not in the manual?

Villeroy & Boch R6L Specifications

General IconGeneral
BrandVilleroy & Boch
ModelR6L
CategoryHot Tub
LanguageEnglish

Related product manuals