17
41002 - 41005
Automatic procedure for assigning IDs to Indoor Stations
This procedure allows the automatic routing of Indoor Station IDs.
N.B.: the Electronic unit from which this configuration is performed, if vertical, must be Master.
Whereas if it is horizontal, it must function as Master via appropriate programming of one or more routers Art. 69RS.
N.B.: the assignment varies according to the Indoor Station used, see specific documentation for details.
Press repeatedly, until the
LEDs light up as in the
previous section, to select
the function.
The electronic unit LEDs
begin to flash slowly
Press to start the
procedure
Request the assignment from
an Indoor Station (*).
The main Indoor Station must
be assigned first, followed by
its secondary indoor stations,
where present.
Press the push button
from which the automatic
assignment of IDs to
Indoors Stations requesting
it will begin
After each successful assignment,
the Electronic unit automatically
emits a verification call towards the
recently encoded Indoor Station
< 5m
beep
After each completed assignment, you have a further 5 minutes to do the next one
< 5m
beep