Gasifying boilers VIGAS
Boiler assembly must be done by specialists of assembly firms.
Boiler need not be placed on a firm base.
Minimum temperature of reversible water at boiler inlet is 60
0
C.
Boiler room must be ventilated permanently through the opening of min. diameter 0,025
m
2
. The diameter for air inlet and outlet must equal approximately.
Boiler must be installed in the surrounding that is common, basic in accordance with the
standard, STN 33 2000-3.
Work and health safety regulations must be followed in accordance with current
instruction requirements, UBP SR No. 718/2002 Coll. and seq.
Z hľadiska požiarno-technické vlastnosti hmôt v blízkosti kotla musia byť splnené
požiadavky normy STN 73 0823:1983/z1 - Stupeň horľavosti stavebných hmôt.
18.2 Safety regulations for control and maintenance of VIGAS boiler electric
equipment
The boiler operator must follow relevant regulations and standards, as well as the following
principles:
If boiler is in operation, none of the following may be done with electric equipment:
o uncover electronic equipment, e.g. boiler electronics, fan, thermostat,
o to exchange fuse,
o to repair damaged cable insulation etc.
Maintenance and repairs of boiler with uncovered electric equipment may only be done by
persons authorized to do so according to 74/1996 Coll.
Before uncovering boiler or any electric equipment connected to boiler, it is necessary to
disconnect any mains /unplug/. You can only plug in after placing covers on original
places.
If there is any defect of electric equipment or boiler installation is damaged it is important: - do
not touch any part of boiler
o disconnect boiler from mains /unplug/.
o to call an authorized service technician that will correct defect.
Apart from common maintenance of boiler, it is strictly forbidden:
to manipulate electric equipment and boiler installation if plugged in,
to touch damaged electric equipment and boiler installation, mainly damage cable insulation ,
etc.,
o to operate boiler if uncovered,,
o to operate boiler with defective electric equipment or defective boiler installation,
o to repair damaged boiler electric parts by persons unauthorized by the producer