Step 1. Remove the plastic separator from the battery.
Step 2. Press to turn on the light.
Step 3. Press to setup brightness for VEG channel. Using and , select the
desired brightness. Press to save settings.
Step 4. Press , repeat step 3 to setup brightness for BLOOM channel.
Step 5. Press to setup current time of day, the hour will flash. Using and ,
select the desired hour. Press or to save the hour and activate the minutes.
Using and , select the desired minutes. Press to save settings, or wait
about 3 seconds and the programmed time will be automatically saved.
OK
OK
VEG
BLOOM
CLOCK
02
Setting system with Remote
Step 6. Press to setup light's start-working time, the hour will flash. Using and
, select the desired start-working hour. Press or to save the hour and
activate the minutes. Using and , select the desired minutes. Press to
save settings, or wait about 3 seconds and the programmed time will be automatically
saved.
Step 7. Press , repeat step 6 to setup light's off-working time.
Step 8. Press to confirm that the system has saved the desired start-working and
off-working time.
PREVIEW
ON
OFF
OK
Using Suggestions
Height (above plants' canopy)
Using Hours
Brightness (VEG/BLOOM)
10 on / 14 off 40 / 15
60 / 30
100 / 60
100 / 100
30” - 34”3-5 days acclimation period
Vegetative Stage
Flowering Stage
26” - 30”
20” - 26”
16” - 20”
12 on / 12 off
12 on / 12 off
18 on / 6 off
VT300
Seedlings/ Young vegetative
Specifications:
Model:
LED Power:
Actual Power Draw:
LED Quantities:
Total Harmonic:
Input Voltage:
Frequency:
VT300
300W
134W±3%
60pcs Epiled/Bridgelux
LEDs
AC100-240V
50-60Hz
HID Replacement:
Vegetative Coverage at 24":
Flowering Coverage at 18":
Use for:
Housing Dimensions:
Item Weight:
Lifespan:
250W HPS/MH
2.5x2.5ft
2x2ft
all stages grow and flowering
15.7 x 8.3 x 2.6 inches
7.6 lbs
100,000 hours
15%
<
IR
2pcs look dim
MODEL: VT300
USER INSTRUCTIONS
Timer Control Series
www.viparspectra.com
For flowering stage: use all channels with 100% brightness.
This light includes IR (Infrared) LEDs which look dim/invisible, they are not faulty LEDs.
PREVIEW
OK
VEG
BLOOM
ON
CLOCK
OFF
VIPARSPECTRA
To setup brightness for
BLOOM channel.
To setup light's start-working
time.
To setup light's off-working
time.
To setup brightness for
VEG channel.
To setup current time of day.
To turn ON/OFF the light.
To increase value.
Switch to other setting.
To decrease value.
Switch to other setting.
To save settings.
To preview start-working
and off-working time.
Note: Timer controls both channels on/off together. Cannot turn VEG and BLOOM channel
on/off separately.
Adjust the height and brightness accordingly to desired coverage and how well each individual
plants responds as the brightness increases. The key is to always observe your plants and listen
to what they're telling you. If the leaves are pointing hard towards the light, they love it! Give
them more! If they shy away or appear limp and unhappy, while all other components and
environmental variables are correct, back off with the light! They'll let you know very quickly how
they feel. This is of course... the key to horticulture in general.
The following section will help guide you in the process of evaluating the best methods
for each stage of plant growth. Like many other growers, you can use this light throughout
the seeding and flowering stages of your plants life. Remember to properly adjust the height
and brightness of your light according to your plants desired level for optimal growth.
Question and Answer IconNeed help?

Do you have a question about the VIPAR SPECTRA Timer Control VT300 and is the answer not in the manual?

Summary

User Instructions

Setting System with Remote

Instructions for setting the timer and light operation using the remote control.

Product Specifications

Technical details of the VT300 light, including power, coverage, and physical dimensions.

Growth Stage Suggestions

Guidance on adjusting light height and brightness for different plant growth phases.

Setting System with Control Knob

Digital Display Overview

Description of main menus and sub-menus for the control knob interface.

Setting Process with Control Knob

Step-by-step guide for configuring timer settings using the control knob.

Control Knob Actions Overview

Summary of actions and their corresponding functions for the control knob.

Warranty Terms and Conditions

Warranty Coverage and Claims

Details on the three-year warranty, exclusions, and procedures for USA and international buyers.

Customer Service Contact

Information on how to contact customer support for warranty assistance and inquiries.

VIPAR SPECTRA Timer Control VT300 Specifications

General IconGeneral
ModelVT300
TypeTimer Control
BrandVIPAR SPECTRA
Voltage100-240V AC
Max Load300W
DisplayLCD
MaterialPlastic
TimerYes
Timer Range24-hour
DimmableYes (with compatible lights)