Date of last revision: 12.03
CALIBRATION GUIDES
1
TREADMILL.CALIB.REV1
T9700HRT v1.7-2.0
Calibration Guide
STEP 1 ENTER ENGINEERING MODE
• With the SAFETY KEY in place, hold the
“ELEVATION UP”
and
“SPEED DOWN”
buttons for 5 seconds.
““NNOONNEE””
will appear in the
profile window.
• Press
“SPEED UP”
until
““CCOONNFFIIGGUURREE””
appears in the profile window.
Press
“SELECT”
.
• You are now in ENGINEERING MODE.
STEP 2 SET MINIMUM SPEED
•
““PP00 MMIINN SSPPEEEEDD””
will appear in the scrolling window.
““00””
should
appear in the elevation window and
””3333””
should appear in the
speed window. To adjust, Press
“START”
.
• Press the
“SPEED UP”
or
“SPEED DOWN”
button until the elevation
window reads
““3311 -- 3355””
. The running belt should be moving at .5 MPH.
• Press the
“SELECT”
button to update the data.
STEP 3 SET THE HALF MAXIMUM SPEED
• Press the
“ELEVATION UP”
button until the scrolling window reads
““PP11 11//22 MMAAXX””
.
““00””
will appear in the elevation window and
““116666””
will
appear in the speed window. To adjust, press
“START”
.
• Press the
“SPEED UP”
or
“SPEED DOWN”
buttons until the elevation
window reads
““116633 -- 116699””
. The running belt should be moving at 6 MPH.
• Press the
“SELECT”
button to update the data.
STEP 4 SET MAXIMUM SPEED
• Press the
“ELEVATION UP”
button until the scrolling window reads
““PP22 MMAAXX SSPPEEEEDD””
.
““00””
will appear in the elevation window and
““332200””
will appear in the speed window. To adjust, press
“START”
.
• Press the
“SPEED UP”
or
“SPEED DOWN”
buttons until the elevation
window reads
““331177 -- 332200””
. The running belt should be moving at 12 MPH.
• Press the
“SELECT”
button to update the data.
STEP 5 SET MINIMUM ELEVATION
• Press the
“ELEVATION UP”
button until the scrolling window reads
““PP44 EELLEE ZZEERROO””
.
““5599””
will appear in the elevation window and
““5599””
will
appear in the speed window.
• Press the
“SPEED UP”
or
“SPEED DOWN”
buttons until the elevation
window reads
““5566 -- 6622””
. The treadmill should be level.
• Press the
“SELECT”
button to update the data.