8-2_______________________________________________________________________Data
2. In the Delay after acknowledge during download field, enter a time value (in
milliseconds) for a delay in sending commands. This field should be used when
problems in communication is experienced.
3. In the Download Code field, if a value (four hexadecimal digits) is entered, the
PowerMax Remote Programmer uses this value instead of the value in the site
information field when performing login.
Note: If no value is entered in this field, then login is performed using the
download code in the site information table.
Note: For additional use of the download code see Chapter 9: Two Download
codes.
8.2 Using Customized Full Upload/Download Data
Note: The following section applies to PowerMax+ only.
This feature enables selecting only specific data to be uploaded/downloaded in connection
with the PowerMax control panel. This saves significant time in uploading/downloading
data.
1. Check the Enable customizing Full Upload/Download Data field, to enable
uploading/downloading of customized settings.
2. Mark the relevant check boxes to specify the data to be uploaded to the
PowerMax control panel.
Attention: Use the exact same customized fields for both uploading and downloading
in order to prevent inconsistency in the data.
Note: Click the Next/Prev buttons to see all the available fields.
Note: When X-10 Device Settings and PGM are selected, the scheduler becomes
functional (see chapter 6, for further details).
3. Click OK; the PowerMax Remote Programmer submits to memory the updated
data. Pressing full upload/download updates the PowerMax control panel with
the new table settings.
Note: The regular full upload/download does not include a log file, the X-10
scheduler or the PGM scheduler.