D-303973 PowerMaxExpress Installer's Guide 21
The number consists of 6 hexadecimal digits.
Receiver 2 Account No. [Fig 4.5.3(7)] - see note in Fig.
4.5 Detail C
Here you enter the number that will identify your system to
the 2
nd
central station. The account number consists of 6
hexadecimal digits.
PSTN/GSM RCVR1 [Fig 4.5.3(8)] - see note in Fig. 4.5
Detail C
Here you program telephone number of the 1
st
central station
(including area code, 16 digit max) to which the system will
report the event groups defined in Report Events.
PSTN/GSM RCVR2 [Fig 4.5.3(9)] - see note in Fig. 4.5
Detail C
Here you program telephone number of the 2
nd
central
station (including area code, 16 digit max) to which the
system will report the event groups defined in Report Events.
IP RCVR 1 [Fig 4.5.3(10)]
Here you enter the IP address of the IP receiver that is
located in the 1
st
central station.
IP RCVR 2 [Fig 4.5.3(11)]
Here you enter the IP address of the IP receiver that is
located in the 2
nd
central station.
SMS RCVR 1 [Fig 4.5.3(12)]
Here you enter the telephone number of the SMS receiver
that is located in the 1
st
central station.
SMS RCVR 2 [Fig 4.5.3(13)]
Here you enter the telephone number of the SMS receiver
that is located in the 2
nd
central station.
PSTN Report Format [Fig 4.5.3(14)] - see note in Fig.
4.5 Detail C
Here you select the reporting format used by the control
panel to report events to central stations.
The options are: SIA text Contact-ID SIA 4/2
1900/1400 4/2 1800/2300 Scancom (see APPENDIX
D - code lists).
4/2 Pulse Rate [Fig 4.5.3(15)] - see note in Fig. 4.5 Detail
C
Here you select the pulse rate at which data will be sent to
central stations if any one of the 4/2 formats has been
selected in PSTN Report Format.
The options are: 10, 20, 33 and 40 pps.
PSTN Report Retry [Fig 4.5.3(16)] - see note in Fig. 4.5
Detail C
Here you determine the number of times the communicator
will dial the central station’s number via PSTN.
The options are: 2, 4, 8, 12 and 16 attempts.
Note: To comply with UL requirements, the unit shall make
no less than five attempts and no more than ten attempts
to contact the central station.
GSM Report Retry [Fig 4.5.3(17)] - see note in Fig. 4.5
Detail C
Here you determine the number of times the
communicator will try to report via a cellular group (GPRS,
GSM and SMS) to the central station.
The options are: 2, 4, 8, 12 and 16 attempts.
Lan Report Retry [Fig 4.5.3(18)] - see note in Fig. 4.5
Detail C
Here you determine the number of times the
communicator will try to report via the Broadband Module
communication to the central station.
The options are: 2, 4, 8, 12 and 16 attempts.
Auto Test Time [Fig 4.5.3(19)]
Here you determine the time at which the telephone line will
be tested and reported to the central station.
Auto Test Cycle [Fig 4.5.3(20)]
Here you determine the time interval between consecutive
telephone line test messages sent to the central station.
The control panel performs this at regular intervals to
verify proper communications.
The options are: test every 5 hours, test every 1, 2, 5, 7,
14, 30 days and test OFF.
Line Fail Report [Fig 4.5.3(21)]
PSTN [Fig 4.5.3(21a)]
Here you determine if the PSTN telephone line
disconnection will be reported or not and determine the
delay between detection of line disconnection and the failure
reporting. If the telephone line is disconnected, the event "tel
line fail" will be stored in the event log.
The options are: don't report, immediately, 5 minutes,
30 minutes, 60 minutes or 180 minutes.
Note: To comply with EN requirements, "immediately"
must be selected.
GSM/GPRS [Fig 4.5.3(21b)]
Here you determine if the GSM/GPRS line disconnection
will be reported or not and determine the delay between
detection of line disconnection and report failure. If the
telephone line is disconnected, the event "GSM line fail"
will be stored in the event log.
The options are: don't report, 2 minutes, 5 minutes, 15
minutes, or 30 minutes.
Broadband [Fig 4.5.3(21c)]
Here you determine if the Broadband Module line
disconnection will be reported or not and determine the
delay between detection of line disconnection and report
failure. If the telephone line is disconnected, the event
"BBA line fail" will be stored in the event log.
The options are: don't report, 2 minutes, 5 minutes, 15
minutes, or 30 minutes
PSTN Up / Down [Fig 4.5.3(22)]
Remote Access [Fig 4.5.3(22a)]
Here you give or deny permission to access the system
and exercise control from a remote telephone.
The options are: rem. access ON and rem. access OFF.
Mast. Downl Code [Fig 4.5.3(22b)]
Here you determine the master installer 4-digit password for
downloading/uploading data into/from the PowerMaxExpress
memory.
Attention! If "0000" is used, it will not enable connection of
the PowerMaxExpress to the PC for upload/download
purpose.
Inst. Downl Code [Fig 4.5.3(22c)]
Here you determine the installer 4-digit password for
downloading data into the PowerMaxExpress memory.
Attention! If "0000" is used, it will not enable
connection of the PowerMaxExpress to the PC for
upload/download purpose.
Upload Option [Fig 4.5.3(22d)]
Here you determine whether the PowerMaxExpress data can
be uploaded into a computer while the system is in disarm
state or at any time (in HOME/AWAY arming & disarm state).
The options are: when system OFF and any time
Up Download Tel# [Fig 4.5.3(22e)]
Here you enter the telephone number (up to 16 digits) of the
UL/DL server.
Note: Only for use with control panels monitored by
compatible central stations. Leave empty if not used.

Table of Contents

Other manuals for Visonic POWERMAXEXPRESS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMAXEXPRESS and is the answer not in the manual?

Visonic POWERMAXEXPRESS Specifications

General IconGeneral
BrandVisonic
ModelPOWERMAXEXPRESS
CategorySecurity System
LanguageEnglish

Related product manuals