QuickFit Kit Easy Start Guide
9) Trouble Shooting
Q Display - The system display shows [NOT READY] or [NOT
READY - TROUBLE]
A There is a fault outstanding, press the status button on any
keyfob or press the
button repeatedly and listen to each
message. Any “…Alarm” messages i.e. “Hall Tamper Alarm” can
be ignored however, zone and tamper open messages need to
be addressed i.e. “Hall Tamper OPEN”.
Q – Display - How do I clear the [READY - MEMORY] message?
A Press the status button on the Keyfob or press
repeatedly
to review the memory condition. Start the ARMING process then
disarm the system. The memory prompt should be cleared.
Q - Tamper - I have tted a sensor with cover closed but the
system is saying the tamper is OPEN, what is wrong?
A - Typically this can happen on PIR sensors when the back plate is
not tted well or the PCB board is incorrectly positioned. Remove
the PCB and check that the back tamper clicks when you ret it,
then replace the cover again listening for the tamper to click.
QSiren - The internal siren will sound on the control panel but
will not sound the external siren
A - This is due to the abort time found in the Installer mode-
‘Dene Panel’-menu 5. If this is set to above 0 seconds it will
delay the external siren and telephone communications.
QCommunication - I have entered the private phone numbers
but the panel does not dial when the system is triggered.
A – You need to also enable option 20 in the dene Coms menu.
See section 8 for more details.
Q Panic I am pressing the keyfob or panel panic buttons but
nothing happens.
AYou need to enable this facility to operate. In installer mode
press
until you see [Dene Panel] then press
. Press
next until [12: Panic Alarm] then press
then press
to select the type (Silent or Audible) pressing
,
to
conrm.
Q Diagnostics When I test the devices the diagnostic screen
says certain devices are [NOT OK]
A Each time you enter the Diagnostic menu the previous
reading are cleared and system needs to see a new signal from
the device. Simply repeat the test but make sure the device is
triggered (tamper or alarm)
11) User Setting and Operation. Within the user settings
you can add/delete keyfobs, set time and date, program phone
numbers etc. To select any of these options enter the user menu by
pressing
until [User Settings] is shown, then
. Pressing
then
, whilst in the menu will allow you to access the
programming option. Remember if you are changing a setting
you need to press the
key twice.
User operation is via the keypad or keyfob (supplied).
When receiving a phone call from the PowerMax System the
user will hear the House ID message followed by the type of
activation. The call must be acknowledged to prevent the system
contacting other Key-holders. To acknowledge press the 2
button on the telephone keypad or 6” if you would like to listen
and talk through the PowerMax. Refer to your user guide for
more options.
You can also control the PowerMax remotely by ringing in. To do
this call the PowerMax / House phone number, let it ring twice
then hang up. Wait 20 seconds, then call again. You will hear a
modem type tone, then :-
Press ‘*’, then your user code, followed by ‘#’
You are now logged in and can use commands like:-
*, 1, # to Disarm the system
*, 3, # to Arm the system
*, 9, # to investigate the system status
*, 99,# to log off
For more options and instructions on how to ring in to the L
system consult the User guide.
NEED HELP? Trade customers only call Visonic Product Support
on 0870 7300830 or email productsupport.uk@visonic.com
End users should contact their place of purchase.
Other products in the Visonic range:-
PowerMax and Next are registered trademarks of Visonic Ltd. Other names
are the property of their owners. Visonic reserves the right to change information or
specications without notice. D-302605 (Rev.00)
MCT-425 Optical Smoke Detector
LPCP approved
MCT-442 CO Sensor
With inbuilt sounder, a
must for every home
MCT-550 Flood Sensor
Detects early signs of
ooding within the home
MCT-220 – Single push button
Ideal for panic or emergency
applications
MKP-150
Two way keypad
MCM-140
Single way keypad
MCT-124 – Double push
Handheld panic button
TOWER-20 MCW
Wireless External detector

Other manuals for Visonic POWERMAX+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMAX+ and is the answer not in the manual?

Visonic POWERMAX+ Specifications

General IconGeneral
TypeWireless Security System
Zones30
CommunicationPSTN
KeypadYes
SirenBuilt-in
Remote ControlYes
Wireless Frequency868 MHz
KeypadsUp to 8
HumidityUp to 85% non-condensing

Related product manuals