Position the water storage tank as near to the VistaPure system board as possible, at the same level�
The system board and storage tank can be separated by up to 30 feet (9 meters), as long as they’re
on the same level and there are no significant “dips” in the tank line tubing, which could create back
pressure�
Locate the white elbow tank valve in the accessory pack and attach valve to the top of the storage
tank� Hand-tighten only—never use tools on system valves and fittings! Make sure to open the tank
valve after installing it on the tank—the system will not work if the tank valve is closed� (A valve handle
in the open position is in line with the tubing; when closed, it is 90° to the tubing�)
Check the air pressure pre-charge in the water storage tank according to the maintenance
instructions on page 12�
After all tubing connections have been made, turn the cold water supply valve on to allow water to
enter the system� Allow it to run for at least 10 minutes� Wastewater should run to the drain and a
pulsing/ clicking sound should be audible from the permeate pump—this is normal� Check for leaks at
all connections�
Sanitize the storage tank and faucet following the maintenance instructions on page 13
After installing the system, checking the air pressure in the storage tank, and sanitizing the tank and
faucet, the VistaPure system is ready for use� Depending on the city water pressure, filling the storage
tank completely (up to 4�25 gallons for the standard tank) may require about an hour� However, water
can be used any time after about 30 minutes, as the system can send water to the wand and faucet
even while making new water
7
9
11
8
10
12