VITA - Vacumat 300
Operating Manual
0
1 2 3
4 5
#
6
97 8
600°C
600°C
500°C
930°C
055°C/min
6:00 min
6:00 min
1:00 min
Question and Answer IconNeed help?

Do you have a question about the vita Vacumat 300 and is the answer not in the manual?

vita Vacumat 300 Specifications

General IconGeneral
Brandvita
ModelVacumat 300
CategoryMedical Equipment
LanguageEnglish

Summary

Technical Data

Controls and Display

Power ON/OFF and Lift UP/DOWN

Controls for powering the furnace and adjusting the firing tray lift.

LCD Display and Function Keys

The main screen and multi-function keys for navigation and program selection.

Start and Stop Buttons

Buttons used to begin a firing program or to halt operations.

Numerical Block

Keypad for entering program numbers and parameter values.

Installation and Standby Temperature

Option Menu

Option Menu Items

Lists adjustable settings like standby temperature, display brightness, and language.

Selecting and Checking Programs

Entering and Altering Parameters

Pre-drying, Rise, and Hold Parameters

Settings for pre-drying, rise time, hold time, and final temperature.

Vacuum and Cooling Settings

Configuration of vacuum pump operation and cooling phases during firing.

Firing Cycle Charts

Soldering Procedures

Soldering Method 1

Describes preheating restoration with flux and solder at 400°C for 15-20 mins.

Soldering Method 2

Describes preheating restoration with flux but no solder at 400°C for 15-20 mins.

VITA Spectra-Seal Calibration

Details factory calibration settings for VITA Spectra-Seal including temperature and times.

VITA Metal-Corrector Calibration

Details factory calibration settings for VITA Metal-Corrector including temperature and times.

VITA Hi-Ceram / VITADUR N / VITA Pt Specific Applications

Refractory Die and Spacer Operations

Procedures for refractory dies and spacers in VITA Hi-Ceram systems.

Core Firing and Cervical Porcelain

Firing parameters for core build-ups and cervical porcelain layers.

Platinum Foil and Glaze Firing

Steps for oxydizing platinum foil and performing various glaze firings.