vita Vacumat 500 Specifications

General IconGeneral
Firing chamber volumeØ 90 mm/3.54 inch, height 80 mm/3.15 inch
Firing tray usable areaØ 90 mm
Max. firing temperature1200 °C
Temperature accuracy+/- 1 °C
VacuumYes
Programs200
Voltage220 – 240 V, 50/60 Hz or 100 – 120 V, 50/60 Hz
Power consumptionmax. 1.5 kW
Dimensions (W x H x D)320 x 370 x 470 mm / 12.6 x 14.6 x 18.5 inch
Weight28 kg / 62 lbs
TypeFiring furnace
Power SourceElectrical
CapacityFiring chamber volume: Ø 90 mm/3.54 inch, height 80 mm/3.15 inch
UsageDental ceramic firing

Summary

Technical Specifications

Safety Advice

General Electrical Safety

Precautions before electrical connection and safe operation.

Installation and Starting-Up

Positioning and Electrical Connection

Steps for positioning the furnace and connecting power and vacuum.

Initial Operation and Tray Placement

Instructions for powering on the furnace and placing the firing tray.

Control Panel Operation

Blocks A & B: Display and Pre-drying

Shows temperature/program status and controls pre-drying settings.

Adjusting the Firing Chamber Temperature

Changing the Muffle

Safety and Preparation for Muffle Change

Emphasizes qualified technicians and power disconnection.

Muffle Replacement Procedure

Detailed instructions for removing and replacing the muffle.

Error Messages and Service

Common Error Messages and Causes

Lists common errors (Err 1-4, Err M) and their potential causes.