EasyManua.ls Logo

VITO VICSOS25 - Frequently Asked Questions; Troubleshooting; Motor Start-up Problems; Low Pressure or Discharge Issues; Overload and Overheating Issues

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41
FREQUENTLY ASKED QUETIONS/ TROUBLESHOOTING
Question/problem - cause
Cause
Solution
The motor does not start or turns slowly:
No supply voltage;
The supply voltage is too low;
The temperature is too low;
Failure in the pressure switch;
Failure in the motor;
Check the plug, socket and circuit breaker of the
power supply circuit;
Avoid too long extension cords;
Use an extension cord with enough transversal
cross-section;
Do not operate the compressor with outside
temperatures below +5°C;
Repair or replace;
Repair or replace;
The compressor runs, but has not enough pressure or
has a low discharge capacity:
The air filter is clogged;
There is a leak in the check and safety valve;
There is a leak in the discharge pipe;
The seals are damaged;
The tank drain plug is leaking;
The cylinder and segments are damaged;
Clean or replace;
Check and repair the valve;
Check and repair;
Replace the damaged seals;
Screw the tank drain valve tightly;
Check the screw’s joint and replace, if necessary;
Repair or replace;
The air compressor stops and the overload relay trips:
Motor overheating;
There is blockage or damage to rotating parts,
which causes the motor to overheat;
Let the compressor cool down, reset the overload
relay and switch the compressor back on;
Remove or replace the parts, press the overload
relay trip button and restart the compressor;
The compressor runs, the pressure is shown on the
pressure gauge, but the air tools do not function:
There is a leak in the compressed air hose;
There is a leak in the quick-release coupling;
The pressure set in the pressure regulator is too
low;
Check the compressed air hose and tools. Replace
them, if necessary;
Check quick-release coupling and replace if
necessary;
Increase the pressure in the air outlet pressure
regulator;
Abnormal noise or vibrations:
Loose parts or connection accessories;
Strange elements inside the motor;
The moving parts are damaged;
Check and retighten;
Check and clean;
Repair or replace;

Table of Contents