EasyManua.ls Logo

Vivotek FD816B-H(T) - Page 247

Vivotek FD816B-H(T)
314 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
User's Manual - 247
- (disabled) : UI turns grey and users
can't select it.
- (unchanged) : UI keeps the status as
before and
user can't change it.
- (hidden) : UI is hidden.
- (fixed) : UI is fixed to one selection or
value.
- (ranged) : UI is fixed to multiple
selections or values.
"Affect API name" can be described in
hierarchy, such as
"exposurewin.mode.blc:disabled:"
which means blc exposure window is
disabled. API name can be one word as
well, such as "exposurelevel:fixed:6"
which means exposurelevel is fixed to
level 6.
"Value" can be a nonnegative integer
or NULL.
"-" means no feature is affected.
* Only available when shutterpriority is
listed in "capability_image_c<n>_
exposure_modetype" and
"capability_image_c<n>_
exposure_mode" is 1.
* We support this parameter when the
version number (httpversion) is equal
or greater than 0302a.
exposure_irisprioritymod
e_affect
-,
exposurewin.mode.blc:hidd
en:,
defog:disabled:,
wdrpro:disabled:,
exposurelevel:hidden:,
or others
0/7 When exposure mode is enabled,
some features may become
malfunction or be forced to a given
value. The affected functions are list
here.
The format is "Affect API
name":"Policy":"Value"