8.36 Peripheral Control (capability_peripheral_c<0~(n-1)>_
devicecontrol > 0)
Note: This request requires Administrator privileges.
Method: GET/POST
Syntax: (for control API)
http://<servername>/cgi-bin/admin/peripheral.cgi?channel=<value>&operation=set
[&washer_mode=<value>] Set washer mode
[&washer_status=<value>] Set washer status
[&washer_dwelltime=<value>] Set washer clean time
[&heater_status=<value>] Set heater status
Example:
http://myserver/cgi-bin/admin/peripheral.cgi?channel=0&operation=set&washer_mode=wiper&
washer_status=on
Response:
HTTP/1.0 200 OK\r\n
Cache-control: no-cache\r\n
Pragma: no-cache\r\n
\r\n
"washer_mode : OK\r\n"
"washer_status : FAIL\r\n"
PARAMETER VALUE DESCRIPTION
channel 0~"capability_nvideoin"-1 Channel of the video source.
washer_mode wiper Apply the wiper to the mode of washer
control system.
*Only available when
capability_peripheral_c<0~(n-1)>_washer
_support=1
washer Apply the washer to the mode of washer
control system.
*Only available when
capability_peripheral_c<0~(n-1)>_washer
© 2019 VIVOTEK INC. All Right Reserved
265
PARAMETER VALUE DESCRIPTION
_support=1
washer_status on Enable the functionality of washer
control system.
*Only available when
capability_peripheral_c<0~(n-1)>_washer
_support=1
off Disable the functionality of washer
control system.
*Only available when
capability_peripheral_c<0~(n-1)>_washer
_support=1
washer_dwelltime 15~999 Apply washer washer control system
operation time (including the time when
spraying and wiper actions take place).
*Only available when
capability_peripheral_c<0~(n-1)>_washer
_support=1
heater_status auto automatic control the heater component
to keep the device in a workable
environment.
*Only available when
capability_peripheral_c<0~(n-1)>_heater
_support=1
trigger
heater component is work in force heater
once.
*Only available when
capability_peripheral_c<0~(n-1)>_heater
_support=1
Syntax: (for query API)
http://<servername>/cgi-bin/admin/peripheral.cgi?channel=<value>&operation=get
[&supportdevice] Get support peripheral device
[&washer_supportmode] Get washer support modes
[&washer_mode] Get washer mode
[&washer_status] Get washer status
[&washer_dwelltime] Get washer clean time
[&heater_supportstatus] Get heater support control status

Other manuals for Vivotek FD9366-HV