[&heater_status] Get heater status
Example:
http://myserver/cgi-bin/admin/peripheral.cgi?channel=0&operation=get&supportdevice&washer_
status
Response:
HTTP/1.0 200 OK\r\n
Cache-control: no-cache\r\n
Pragma: no-cache\r\n
\r\n
supportdevice=washer,heater\r\n
washer_status=off\r\n
PARAMETER VALUE DESCRIPTION
channel 0~"capability_nvideoin"-1 Channel of the video source.
supportdevice N/A Get support peripheral device.
washer_supportmode N/A
Get the support mode of washer control system,
its value is the same with
"capability_peripheral_
c<0~(n-1)>_washer_mode".
*Only available when
capability_peripheral_c<0~(n-1)>_washer_supp
ort=1
washer_mode N/A
Get the current mode of washer control system.
It return the value of "washer_mode"
* Available values are listed in
"capability_peripheral_c<0~(n-1)>_washer_mod
e"
washer_status N/A
Get the current status of washer control module.
The status is 'off' as default, which means the
washer is stopped; and the status 'on' means the
washer is running.
*Only available when
capability_peripheral_c<0~(n-1)>_washer_supp
ort=1
washer_dwelltime N/A Get the current washer clean period of washer
control system.
© 2019 VIVOTEK INC. All Right Reserved
267
PARAMETER VALUE DESCRIPTION
*Only available when
capability_peripheral_c<0~(n-1)>_washer_supp
ort=1
heater_supportstatus N/A Get the support status of heater control system.
*Only available when
capability_peripheral_c<0~(n-1)>_heater_suppo
rt=1
heater_status N/A
Get the current heater status.
Normally it will be 'auto', it means the heater
device is control by internal algorithm to keep in
a suitable environment; Otherwise is 'trigger', it
means the heater device is force enable to heat
to an internal condition.‘trigger’ status will be
transfer to ‘auto’ after reach the internal
condition.
*Only available when
capability_peripheral_c<0~(n-1)>_heater_suppo
rt=1