EasyManua.ls Logo

Vivotek FD9381-EHTV - Page 262

Vivotek FD9381-EHTV
328 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
262 - User's Manual
trigger boot,
di,
p i r,
motion,
seq,
recnotify,
tampering,
vi,
volalarm,
visignal,
vadp,
smartsd
<product dependent>
6/6 Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“pir”= PIR detection
“motion” = Video motion detection
“seq” = Periodic condition
“visignal” = Video input signal loss.
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
“volalarm”= Audio detection
“smartsd”= Lifetime detection of SD card
triggerstatus string[40] 6/6 The status for event trigger
di 0,<positive integer> 6/6 Indicate the source id of di trigger.
This field is required when trigger condition is
“di”.
One bit represents one digital input. The LSB
indicates DI 0.
mdwin 0,<positive integer> 6/6 Indicate the source window id of motion
detection.
This field is required when trigger condition is
“md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows,
set mdwin as 5.
mdwin0 0,<positive integer> 6/6 Similar to mdwin. The parameter takes effect
when profile 1 of motion detection is enabled.
vi 0,<positive integer> 6/6 Indicate the source id of vi trigger.
This field is required when trigger condition is
“vi”.
One bit represents one digital input. The LSB
indicates VI 0.

Table of Contents

Other manuals for Vivotek FD9381-EHTV

Related product manuals