serverip <IP address> 6/6 Log server IP address.
serverport 514, 1025~65535 6/6 Server port used for log.
level 0~7 6/6 Levels used to distinguish the importance of the
information:
0: LOG_EMERG
1: LOG_ALERT
2: LOG_CRIT
3: LOG_ERR
4: LOG_WARNING
5: LOG_NOTICE
6: LOG_INFO
7: LOG_DEBUG
Group: camctrl
NAME VALUE SECURITY
(get/set)
DESCRIPTION
enablehttptunnel <boolean> 4/4 Enable HTTP tunnel for camera control.
Group: camctrl_c<0~(n-1)> for n channel product (capability.ptzenabled)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
panspeed -5 ~ 5 1/4 Pan speed
tiltspeed -5 ~ 5 1/4 Tilt speed
zoomspeed -5 ~ 5 1/4 Zoom speed
autospeed -5 ~ 5 1/4 Auto pan speed
focusspeed -5 ~ 5 1/4 Auto focus speed
patrolseq string[64] 1/4 (For external device)
The indexes of patrol points, separated by “,”
patroldwelling string[128] 1/4 (For external device)
The dwelling time of each patrol point, separated by “,”
preset_i<0~(npre
set-1)>_name
string[40] 1/4 Name of the preset location.
preset_i<0~(npre
set-1)>_dwelling
0~999 1/4 The dwelling time of each preset location.
uart 0 ~ (m-1), m
is UART count
1/4 Select corresponding uart
(capability.nuart>0).
cameraid 0~255 1/4 Camera ID controlling external PTZ camera.
isptz 0 ~ 2 1/7 0: disable PTZ commands.
1: enable PTZ commands with PTZ driver.