EasyManua.ls Logo

Vivotek IP816A-HP - Page 199

Vivotek IP816A-HP
234 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
User's Manual - 199
exttriggerstatus trigger,
normal~trigger
,
trigger~norma
l
<blank> 6/6 The status for event DI 1 trigger
exttriggerstatus1 trigger,
normal~trigger
,
trigger~norma
l
<blank> 6/6 The status for event audio detection
profiletrigger
di <integer> 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input. The
LSB indicates DI 0.
mdwin <integer> 0 6/6 Indicate the source window id of motion
detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0 <integer> 0 6/6 Similar to mdwin. The parameter takes
effect when profile 1 of motion detection
is enabled.
vi <integer> 0 6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input. The
LSB indicates VI 0.
valevel 0,1 0 6/6 Select audio detection event.
0: not select
1: select
valevel0 0,1 0 6/6 Select audio detection profile event.
0: not select
1: select
inter 1~999 1 6/6 Interval of snapshots in minutes.
This field is used when trigger condition
is “seq”.

Table of Contents