cyclesize 20~ 6/6 The maximum size for cycle recording in Kbytes when
choosing to limit recording size.
reserveamount 100~ 6/6 The reserved amount in Mbytes when choosing cyclic
recording mechanism.
dest cf,
0~4
6/6 The destination to store the recorded data.
“cf” means CF card.
“0~4” means the index of the network storage.
cffolder string[128] 6/6 Folder name.
filesize 1~100 6/6 Unit: Mega bytes.
When this condition is reached,
Recording file is truncated.
duration 1~60 6/6 Unit: Minute.
When this condition is reached,
Recording file is truncated.
trigger schedule,
networkfail
6/6 The event trigger type
Schedule: The event is triggered by schedule
Networkfail: The event is triggered by the failure of
network connection.
adaptive_enable 0,1 6/6 Indicate whether the adaptive recording is enabled.
adaptive_preevent 0~9 6/6 Indicate when is the adaptive recording started before
the event trigger point (seconds).
adaptive_postevent 0~10 6/6 Indicate when is the adaptive recording started after the
event trigger point (seconds).
Group: https (product dependent)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
enable <boolean> 6/6 To enable or disable secure HTTP.
policy <Boolean> 6/6 If the value is 1, it will force HTTP connection redirect to
HTTPS connection
method auto,
manual,
install
6/6 auto => Create self-signed certificate automatically.
manual => Create self-signed certificate manually.
install => Create certificate request and install.
status -3 ~ 1 6/6 Specify the https status.
-3 = Certificate not installed
-2 = Invalid public key
-1 = Waiting for certificate
0 = Not installed
1 = Active