VIVOTEK
358 - User's Manual
*Only available when
capability_peripheral_c<0~(n-1)>_washer_supp
ort=1
off Disable the functionality of washer control system.
*Only available when
capability_peripheral_c<0~(n-1)>_washer_supp
ort=1
washer_dwelltime 15~999 Apply washer washer control system operation
time (including the time when spraying and wiper
actions take place).
*Only available when
capability_peripheral_c<0~(n-1)>_washer_supp
ort=1
heater_status auto automatic control the heater component to keep
the device in a workable environment.
*Only available when
capability_peripheral_c<0~(n-1)>_heater_suppo
rt=1
trigger heater component is work in force heater once.
*Only available when
capability_peripheral_c<0~(n-1)>_heater_suppo
rt=1
Syntax: (for querying API)
http://<servername>/cgi-bin/admin/peripheral.cgi?channel=<value>&operation=get
[&supportdevice] –Get support peripheral device
[&washer_supportmode] – Get washer support modes
[&washer_mode] – Get washer mode
[&washer_status] – Get washer status
[&washer_dwelltime] – Get washer clean time
[&heater_supportstatus] – Get heater support control status
[&heater_status] – Get heater status
Example:
http://myserver/cgi-bin/admin/peripheral.cgi?channel=0&operation=get&supportdevice&washer_status
Response:
HTTP/1.0 200 OK\r\n
Cache-control: no-cache\r\n
Pragma: no-cache\r\n