EasyManua.ls Logo

Vivotek MD9581-H - Page 158

Vivotek MD9581-H
417 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
158 - User's Manual
© 2019 VIVOTEK INC. All Right Reserved
27
6. Set Server Parameter Values
Note: The access right depends on the URL directory.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/anonymous/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>…][&return=<return page>]
http://<servername>/cgi-bin/viewer/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>…][&return=<return page>]
http://<servername>/cgi-bin/operator/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>…][&return=<return page>]
http://<servername>/cgi-bin/admin/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>…][&return=<return page>]
PARAMETER DESCRIPTION
<parameter> A full path like: "videoin_c0_s0_h264_resolution",
"videoin_c0_s0_h264_maxframe", etc.
<value> The assigned <value> to the <parameter>.
<return page> Redirect to the page <return page>after the <parameter> is assigned. The <return
page>can be a full URL path or relative path according to the current path. If you
omit this parameter, it will redirect to an empty page.
(Note: The return page can be a general HTML file (.htm, .html). It cannot be a CGI
command or have any extra parameters. This parameter must be placed at the end
of the parameter list.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: <length>\r\n
\r\n
<parameter pair>
where<parameter pair> is
<parameter>=<value>\r\n