VIVOTEK
User's Manual - 159
© 2019 VIVOTEK INC. All Right Reserved
27
6. Set Server Parameter Values
Note: The access right depends on the URL directory.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/anonymous/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>…][&return=<return page>]
http://<servername>/cgi-bin/viewer/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>…][&return=<return page>]
http://<servername>/cgi-bin/operator/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>…][&return=<return page>]
http://<servername>/cgi-bin/admin/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>…][&return=<return page>]
PARAMETER DESCRIPTION
<parameter> A full path like: "videoin_c0_s0_h264_resolution",
"videoin_c0_s0_h264_maxframe", etc.
<value> The assigned <value> to the <parameter>.
<return page> Redirect to the page <return page>after the <parameter> is assigned. The <return
page>can be a full URL path or relative path according to the current path. If you
omit this parameter, it will redirect to an empty page.
(Note: The return page can be a general HTML file (.htm, .html). It cannot be a CGI
command or have any extra parameters. This parameter must be placed at the end
of the parameter list.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: <length>\r\n
\r\n
<parameter pair>
where<parameter pair> is
<parameter>=<value>\r\n
© 2019 VIVOTEK INC. All Right Reserved
28
[<parameter pair>]
Only the parameters that you set and are readable will be returned.
Example: Set the IP address of server to 192.168.0.123:
Request:
http://myserver/cgi-bin/admin/setparam.cgi?network_ipaddress=192.168.0.123
Response:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: 33\r\n
\r\n