separated by “,”
patroldwelling string[160] <blank> 1/4 (For external device)
The dwelling time of each patrol
point, separated by “,”
7.18 UART control
Group: uart (capability.nuart > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40] <blank> 1/4 Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128] <blank> 1/4 Full path of the PTZ driver.
enablehttptunnel <boolean> 0 1/4 Enable HTTP tunnel channel to
control UART.
Group: uart_i<0~(n-1)> n is uart port count (capability.nuart > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600,120
0,2400,3600,480
0,7200,9600,192
00,38400,57600,
115200
9600 4/4 Set baud rate of COM port.
databit 5,6,7,8 8 4/4 Data bits in a character frame.
paritybit none,
odd,
even
none 4/4 For error checking.
stopbit 1,2 1 4/4 1
2-1.5 , data bit is 5
2-2
uartmode rs485 rs485 4/4 UART transmission mode.
customdrvcmd_i<0~9
>
string[128] <blank> 1/4 PTZ command for custom
camera.
speedlink_i<0~4>_na
me
string[40] <blank> 1/4 Additional PTZ command
name.
speedlink_i<0~4>_c string[40] <blank> 1/4 Additional PTZ command list.