Step 6 — Rinse in detergent
• If the lling process of the carbonator cannot be completed due to high counter pressure, pull the
safety valve (Fig. 1). Use a cloth to absorb any splashing water.
• Draw o the respective types of water as specied by the cleaning program (rst still and still chilled,
then sparkling). End the dispensing process with Next.
• Draw 100 mL sparkling drinks and 50 mL still chilled and still unrefrigerated.
• The tapping process can be interrupted and continued at any time with Pause or Run.
• Put up the information sign. Now let the cleaning agent act for 10 minutes.
• During the entire cleaning process, it must be ensured that no drinking water is drawn o. If the
housing is open, the device must be protected against access. Caution! Danger to life in the event of
electric shock by touching live parts!
Step 7 — Empty the carbonator
• Open the CO2 supply line.
• Close the water supply.
• Tap the soda until only CO2 escapes.