Step 8 — Empty the carbonator
• Remove the service cartridge and insert a new pre-rinsed cold water lter cartridge.
• Open the water supply.
• Place a vessel under the outlet. The cleaning program carries out rinses for all types of water.
The carbonator is completely ooded (overpressure valve must be pulled).
• When rinsing, the water types are changed several times. Due to the short stagnation, residues
of the cleaning solution are released from dead corners.
• The cleaning program from rmware 2.2.9 species 2 rinsing cycles.
• Flush volume sparkling 10 L (2 x 5 L), chilled 5 L (2 x 2.5 L), still 5 L (2 x 2.5 L).
Step 9 — Rinse out cleaning agent