Step 8 — Empty the carbonator
Remove the service cartridge and insert a new pre-rinsed cold water lter cartridge.
Open the water supply.
Place a vessel under the outlet. The cleaning program carries out rinses for all types of water.
The carbonator is completely ooded (overpressure valve must be pulled).
When rinsing, the water types are changed several times. Due to the short stagnation, residues
of the cleaning solution are released from dead corners.
The cleaning program from rmware 2.2.9 species 2 rinsing cycles.
Flush volume sparkling 10 L (2 x 5 L), chilled 5 L (2 x 2.5 L), still 5 L (2 x 2.5 L).