EasyManua.ls Logo

Vmac PREDATAIR - Page 2

Vmac PREDATAIR
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Support
Subject
PREDATAIR Error Codes and Symptoms
Document
Version
Department
Revision Details
Revised by
Tech
Engineering
Implemented
EXT-PRED-016
A
Tech
Document Release
SP 18 Aug 2015
DB 18 Aug 2015
N/A
18 Aug 2015
Page 2 of 8
Figure 1 gives an example of an error code.
Figure 1
Name: __________________________ Phone#: ______________________
Company: _______________________ Email/Fax#:____________________
Date: ________________
Error
Code
Error
1
Compressor has Over Temped
>138C
2
Hydraulic has Over Temped
>88C
3
Not Used
4
Compressor Probe Short
5
Hydraulic Probe Short
6
Not Used
7
Compressor Probe Open
8
Hydraulic Probe Open
9
Not Used
10
Not Used (Battery Voltage)
11
No Pressure Sensor
12
No CAN Bus Connection
When you have reached the end, “NO SVC
NEEDED” will be displayed. Email completed
sheet to techsupport@vmacair.com or fax to
(250) 740-3202
HRS
Time
Error
ERRORS
E
0
1
E
0
2
E
0
3
E
0
4
E
0
5
E
0
6
E
0
7
E
0
8
E
0
9
E
1
0
SERVICE
TIMES
S
0
1
S
0
2
S
0
3
S
0
4
S
0
5
S
0
6
S
0
7
S
0
8
S
0
9
S
1
0