Welcomes the user and highlights the boiler's design and expected reliability with proper care.
Provides essential safety and operational guidelines for the user regarding the boiler and its environment.
Outlines legal requirements for gas appliance installation and maintenance by competent persons.
Specifies correct electrical connection, fused supply, and the requirement for earthing the appliance.
Advises users to complete and post the guarantee registration card within 30 days of installation.
Explains the importance of the Benchmark Log Book for installation, commissioning, and warranty validity.
Describes the boiler's function as a central heating and hot water system, controlled by timers and thermostats.
Lists the physical dimensions of the boiler: height, width, and depth.
Specifies the minimum clearance distances required around the boiler for safe operation and servicing.
Guides users on familiarizing themselves with isolation, pressure checks, controls, and thermostats before operation.
Details the boiler's controls including the mode switch, thermostat, pressure gauge, and programmer slot.
Provides instructions on how to turn on the boiler, setting the mode switch and ensuring heating demand.
Explains the procedure for checking and topping up the central heating system pressure using the filling loop.
Describes the manual reset procedure for the boiler when the reset light is illuminated.
Advises on safely shutting down the boiler and system for temporary periods.
Details the process for draining the system and isolating supplies when the property is left unoccupied for extended periods.
Gives instructions on cleaning the boiler casing using a soft cloth and avoiding abrasive cleaners.
Provides immediate actions to take in case of a suspected gas leak, including turning off supply and contacting professionals.
Advises contacting an installer if the system repeatedly requires topping up, indicating a potential leak.
Explains that the reset light signifies a fault or overheat, requiring manual reset.
Guides tenants and homeowners on arranging annual servicing for the boiler.
Instructs users on what information to provide when contacting customer services or an engineer for fault diagnosis.
Explains how to set the 24-hour mechanical time clock for automatic boiler operation using pins.
Details how to adjust the pins on the clock face to define the desired ON and OFF periods for the boiler.
Guides the user on setting the current time of day on the mechanical clock face.
Describes the three-position selector switch that overrides programmed times for continuous operation or shutdown.
Explains how to set the current time and day on the Vokera digital time clock.
Instructs on clearing the memory of the programmer using the 'Res.' button before setting new programs.
Details the step-by-step process to set the correct day, hour, and minutes on the digital programmer.
Guides on programming the ON times for heating and hot water using the programmer's buttons.
Guides on programming the OFF times for heating and hot water using the programmer's buttons.
Explains how to advance to the next command or lock the time clock to continuous ON or OFF settings.
Offers tips on checking/altering settings, battery backup, and recording programmed times.
Describes how to test programmed ON and OFF times to ensure they are set correctly.
Explains how to set a period where the system remains off before resuming programmed operation.
Outlines the four operational modes for central heating and hot water: OFF, TIMED, ONCE, ON.
Guides on how to change the default programme settings for CH and HW.
Details the operational modes (OFF, TIMED, ONCE, ON) for central heating and hot water independently.
Explains how to access and modify program settings for central heating (CH) and hot water (HW) for weekdays.
Provides tips on using +/- buttons, setting times sequentially, handling errors, and resetting the programmer.
Lists the four operational modes (OFF, TIMED, ONCE, ON) for CH and HW on the 24hr programmer.
Guides on setting the current time and day on the 24hr programmer.
Explains how to modify the standard programme settings for CH and HW.
Details the four operational modes for the 24hr programmer, allowing independent CH and HW control.
Shows the default ON/OFF times for the 24hr programmer for both Hot Water (H/W) and Central Heating (C/H).
| Fuel Type | Gas |
|---|---|
| Warranty | 2 Years |
| Model | Mynute |
| Efficiency Rating | A |
| Mounting | Wall Mounted |
| Type | Combination Boiler |