Setting range is from 5min to
900min. Increment of each click
is 5min.
Battery equalized timeout
Setting range is from 5min to 900
min. Increment of each click is 5
min.
Setting range is from 0 to 90
days. Increment of each click is 1
day
Equalization activated
immediately
If equalization function is enabled in program 30, this program
can be set up. If “Enable” is selected in this program, it’s to
activate battery equalization immediately and LCD main page will
show “ ”. If “Disable” is selected, it will cancel equalization
function until next activated equalization time arrives based on
program 35 setting. At this time, “ ” will not be shown in LCD
main page.
Reset all stored data for PV
generated power and
output load energy
Maximum battery
discharging current
If selected, battery discharge
protection is disabled.