EasyManuals Logo

Vortex CDX2532G User Manual

Vortex CDX2532G
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Unloader Adjustment
1. The rst step is to reset the
unloader. Turn the adjustment
knob counter clockwise until
there is absolutely no pressure
against the spring inside the
unloader.
2. Connect hoses to your pump
and run water to it. Now you will
need to purge the air from your
hoses by pulling the trigger until
only water comes out.
3. Run your pressure washer
4. With your pressure washer
running hold down the trigger
and slowly turn the adjustment
knob clockwise.
5. When pressure no longer
increases turn the knob counter
clockwise 1/2 turn and release
the trigger. NOTE: If the engine
stalls or acts as if it is still under-
load then you will need to repeat
steps 4 and 5 again until your
pressure washer goes into by-
pass mode and there is no load
on the engine.
6. Below the adjustment knob
you will nd a brass stopper
with a set screw. Loosen the set
screw and adjust the stopper
until it is snug against the ad-
justment knob. Tighten the set
screw to keep it in place

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vortex CDX2532G and is the answer not in the manual?

Vortex CDX2532G Specifications

General IconGeneral
BrandVortex
ModelCDX2532G
CategoryWater Pump
LanguageEnglish

Related product manuals