NOTE: Please choose a suitable location for your grounding system.
Your grounding system must be:
at least 10 m away from other grounding systems, such as ground connections of
homes, telephone or power lines.
away from animals or pathways as animals or people may damage the grounding.
accessible to you at any time for maintenance purposes.
If you run any connection cables through the inside of buildings, you must always use
insulated high-voltage cables.
5. THE IDEAL FENCE
Regardless of the types of conducting material used in your fence, there are a few
things to keep in mind in order to ensure good conductivity.
Keep your electric fence system free from vegetation. Do not run your fence through
hedges and avoid having any branches or bushes complete the circuit.
This will reduce the voltage on your fence and the shock strength of the electrical pulse
may no longer be powerful enough.
Ensure that the conducting material in your fence does not touch the ground,
e.g. by sagging.
Only use fence posts with insulators so as to insulate the conducting material from
the post and the ground. This will prevent any loss of voltage and ensure the desired
current ows through the conducting material of the fence.
Suitable accessories are available for using metal posts and industrial fences.
NOTE: It is a legal requirement to place warning signs on the fence in publicly accessible
areas, such as item no. 44735.
6. INITIAL SETUP:
NOTE: The following steps will help you activate the energiser. Your fence will
then be live. Make sure that there are no people or animals near the fence.
When the energiser is connected to the fence it constantly checks for faults. If the LED
bar (4) is red, there is a fault on the fence. Meaning your fence security is compromised.
Check your fence for faults.
In order to achieve the best possible safety, the following minimum conductor spacing
is recommended:
140 cm
100 cm
50 cm
110 c m
85 cm
60 cm
40 cm
20 cm
105 cm
75 cm
45 cm
85 cm
60 cm
40 cm
20 cm
70 cm
40 cm
20 cm
120 cm
75 cm
45 cm
Horses
Goat
Cattle
Poultry
Domestic pigs
Pony
90 cm
65 cm
40 cm
20 cm
140 cm
105 cm
75 cm
45 cm
30 cm
Sheep
Deer
DE UK FR IT NL SE