AOM701 Troubleshooting Guide
Monitor will not power up – no backlight on power button
Confirm 12v+ to monitor.
Confirm ground connection.
Check vehicle’s fuse and circuit for proper operation.
No image on screen
Verify monitor is on correct camera input.
Verify cable is connected to monitor.
Verify camera is connected to cable.
Connect known good camera and cable to monitor.
o If image appears connect cable to existing camera.
If image remains replace original cable.
If image disappears replace original camera.
Inputs do not trigger properly (Standby or otherwise)
See owner’s manual for proper wiring.
Confirm 12v + to each appropriate trigger lead.
o Note: Trigger will remain active as long as there is 12VDC+ to that wire,
preventing control or access to other inputs/cameras.
No audio
Verify selected camera supports audio.
Verify volume setting.
Confirm that the audio trigger (WHITE wire in monitor’s power harness) is
connected to 12v+.