EasyManua.ls Logo

Wabtec Microphor LF-210 - User Manual

Default Icon
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
452 East Hill Road Fax: 707.459.6617
Willits, CA 95490 USA E-mail: info@microphor.com
Phone: 707.459.5563 www.microphor.com 24533.WPD
Toll Free: 1.800.358.8280 www.wabtec.com 10/19/01
Model LF-210 Model LF-219
Model LF-310 Model LF-320
Microflush Half Gallon Toilets
Marine Heads
Air Operated
Installation/Service Manual
P/N 24533

Questions and Answers

  • R
    Ruben HudsonAug 20, 2025
    What to do if water splashes when flushing Wabtec Microphor LF-210?
    • C
      Catherine MorganAug 20, 2025
      If water splashes when flushing Wabtec Toilets, it could be due to the water level in the bowl being too high. Try reducing the incoming water via the angle stop and re-adjust the cycle time.
  • K
    Kathy BatesAug 22, 2025
    Why is the flush cycle too long on my Wabtec Microphor LF-210?
    • L
      lopezjenniferAug 22, 2025
      If the flush cycle is too long on your Wabtec Toilets, the bleed-off plug might be blocked. Remove, clean, or replace it, and then reinstall.
  • S
    scrawfordAug 25, 2025
    What to do if the flapper opens and closes 4-8 seconds after handle is released, but no water enters the bowl in Wabtec Toilets?
    • K
      Kimberly VillegasAug 25, 2025
      If the flapper opens and closes 4-8 seconds after the handle is released, but no water enters the bowl in Wabtec Toilets, the possible causes are: * No water supply to Microflush. To solve this, supply water at 20-50 psi at the toilet. * Water turned off. To solve this, open the angle stop (shut-off valve).
  • L
    Lee HollandAug 26, 2025
    What to do if Wabtec Toilets flush cycle is too short?
    • A
      alexisortizAug 27, 2025
      If the flush cycle is too short, the bleed-off plug hole might be too large, or related air lines could be leaking. Remove and replace the plug, and check for air line leaks.
  • D
    davidhernandezAug 28, 2025
    What to do if water continues to run when Microflush is not in use in Wabtec Microphor LF-210?
    • D
      David FoleyAug 28, 2025
      If water continues to run when the Microflush is not in use, a foreign object might be under the water valve in the Air/Water Sequence Valve. Clean the Air/Water Sequence Valve, referencing Service Kit P/N 95057.
  • K
    Kevin HamiltonAug 30, 2025
    What to do if flapper opens when flushed, and closes immediately when activator is released in Wabtec Microphor LF-210 Toilets?
    • C
      Christopher GarrisonAug 30, 2025
      If the flapper opens when flushed and closes immediately when the activator is released, it could be due to: * Excessively high water pressure. Install a water pressure regulating valve, set at 20-50 psi. * Debris in the check valve at the base of the Air/Water Sequence Valve. Clean the Air/Water Sequence Valve.
  • S
    smithtaraSep 1, 2025
    How to fix Wabtec Microphor LF-210 when the flapper opens and will not close?
    • M
      Madeline KramerSep 1, 2025
      If the flapper opens and will not close on Wabtec Toilets, the bleed-off plug might be blocked. Remove, clean, or replace it, and then reinstall.
  • H
    Harold ShafferSep 2, 2025
    How to fix Wabtec Toilets when the flapper does not open, water does not flow, and nothing happens?
    • M
      Maria JohnsonSep 3, 2025
      If the flapper does not open, water does not flow, and nothing happens with your Wabtec Toilets, it could be due to: * No Air Supply to Microflush. Supply compressed air at 60-65 psi at the toilet. * Water has accumulated in Air/Water Sequence Valve. See 'Check Air System' above.
  • T
    Tabitha MccoySep 4, 2025
    What to do if Wabtec Toilets water keeps running?
    • K
      Kevin DennisSep 4, 2025
      If water continues to run when the Wabtec Microflush toilet is not in use, a foreign object might be under the water valve in the Air/Water Sequence Valve. Clean the Air/Water Sequence Valve. You may also reference Service Kit P/N 95057.
  • H
    Heather WilliamsSep 6, 2025
    Why Wabtec Toilets flapper opens and will not close?
    • J
      Jason HigginsSep 6, 2025
      If the flapper opens and will not close on your Wabtec toilet, the bleed off plug may be blocked. Remove, clean, or replace the bleed off plug, then reinstall it.

Summary

Pre-Installation and System Overview

Pre-Installation Steps

General procedures before installing the marine head, including unpacking and model-specific notes.

Installation Procedures

Air Lines

Guidelines for air line sizing, filter-regulator installation, and connections.

Drain Connection

Instructions for drain connections, including rough-in dimensions and pipe slope.

Water Connection and Startup

Water Connection

Instructions for connecting water supply, including integral and remote models.

Start Up

Procedure for turning on air and water supplies and flushing the system.

Maintenance, Cleaning, and Troubleshooting

Troubleshooting

Common issues and their solutions for water supply, air system, and cycle time.

Component Procedures

Air;Water Sequence Valve Operation

Detailed explanation of the air/water sequence valve's function.

Rough-in Dimensions

Remote Flush Rough-In

Rough-in dimensions for remote flush installations.

Wabtec Microphor LF-210 Specifications

General IconGeneral
BrandWabtec
ModelMicrophor LF-210
CategoryToilets
LanguageEnglish