Questions and Answers

  • T
    Teresa BellAug 13, 2025
    What to do if Wabtec Toilets water keeps running?
    • S
      Shannon MunozAug 13, 2025
      If water continues to run when the Wabtec Microflush toilet is not in use, a foreign object might be under the water valve in the Air/Water Sequence Valve. Clean the Air/Water Sequence Valve. You may also reference Service Kit P/N 95057.
  • A
    Allison RuizAug 16, 2025
    Why Wabtec Toilets flapper opens and will not close?
    • C
      Christopher GarrettAug 16, 2025
      If the flapper opens and will not close on your Wabtec toilet, the bleed off plug may be blocked. Remove, clean, or replace the bleed off plug, then reinstall it.
  • S
    Shannon ChandlerAug 20, 2025
    What to do if Wabtec Toilets flapper closes immediately after flushing?
    • N
      ngallagherAug 20, 2025
      If the flapper opens when flushed and closes immediately when the activator is released on your Wabtec toilet, it could be due to excessively high water pressure. Install a water pressure regulating valve, set at 20-50 psi. Alternatively, there may be debris in the check valve at the base of the Air/Water Sequence Valve; in this case, clean the Air/Water Sequence Valve.
  • C
    christophermurphyAug 25, 2025
    Why is the flush cycle too short on Wabtec Toilets?
    • D
      Donald TranAug 25, 2025
      If the flush cycle is too short on your Wabtec toilet, there may be an air line leakage. Check for air leakage at all connections.
  • F
    freynoldsAug 28, 2025
    How to fix too long flush cycle on Wabtec Toilets?
    • D
      Dennis HallAug 28, 2025
      If the flush cycle is too long on your Wabtec toilet, the bleed-off plug may be blocked. Remove, clean, or replace it, then reinstall.
  • C
    Christian TuckerAug 31, 2025
    What to do if Wabtec Toilets flapper opens and closes but no water enters bowl?
    • L
      leehenryAug 31, 2025
      If the flapper opens and closes 4-8 seconds after the handle is released, but no water enters the bowl of your Wabtec toilet, it could be due to no water supply to the Microflush. Supply water at 20-50 psi. Another possible cause is that the water is turned off; open the angle stop (shut-off valve).
  • T
    tonyaadamsSep 4, 2025
    How to stop water splashes when Wabtec Toilets are flushed?
    • B
      blanchardchristianSep 4, 2025
      If water splashes when your Wabtec toilet is flushed, the water level in the bowl might be too high. Reduce the incoming water flow via the angle stop.
  • L
    Lauren EscobarSep 7, 2025
    What to do if Wabtec Toilets flapper doesn't open and water doesn't flow?
    • C
      Claudia DaySep 8, 2025
      If the flapper does not open, water does not flow, and nothing happens when you flush your Wabtec toilet, it could be due to no air supply to the Microflush. Supply compressed air at 60-65 psi at the toilet. Another possible cause is water accumulation in the Air/Water Sequence Valve.

Summary

Installation Procedures

Drain Connection

Instructions for connecting the discharge line.

Water Connection

Steps for connecting the water supply to the head.

Operation and Maintenance

Start Up

Procedures for initial system startup and testing.

Clearing Your Microflush Head

Steps to resolve blockages in the toilet.

Troubleshooting and Parts

Troubleshooting Guide

Table of common problems, causes, and corrections.

Technical Procedures and Diagrams

Rough-In Dimensions

Key measurements for installation of various models.

Wabtec Microphor LF-310 Specifications

General IconGeneral
BrandWabtec
ModelMicrophor LF-310
CategoryToilets
LanguageEnglish

Related product manuals