EasyManua.ls Logo

Wabtec PROD0842 - Page 43

Wabtec PROD0842
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
CAS-GPS IVU BASIC SYSTEMS INSTALLATION MANUAL DOCU0085 Revision Q
Ground
Ground pickup point is the vehicle chassis. A ring terminal on a designated grounding point should be used.
Ignition Signal
Vehicle ignition should be protected by an independent 4 Amp fuse. Although the system does not draw operating
current from this source, the vehicle’s circuit should be protected against inadvertent shorts.
Basic Reverse & Forward Signals
Unless using a CAT Gear Decoder (see below) the reverse signal should be obtained from the vehicle’s reverse
buzzer or alternatively the reverse lights. The forward signal may be wired from a suitable forward gear indicator, with
the forward negative signal is tied to ground. Pickup should be made on the output side of the relays.
CAT Gear Decoder Reverse & Forward Signals (PROD0587 CAT B,C & D or PROD0724 CAT E & F)
For vehicles using the CAT Gear Decoder, Reverse and Forward signals should be obtained directly from the
decoders outputs observing the correct polarity when connecting to the IVU. Basic Reverse & Forward Signal wiring
is not required when using the Reverse & Forward Signals from the CAT Gear Decoder.
Input Power & Signal Connections