5-2 BA 1404 en – Edition 2.7 * * 1404b510.fm
Maintenance
5.2 Fuel system
Specific safety instructions
Extreme caution is essential when handling fuel – increased fire hazard!
Never perform work on the fuel system near open flames or sparks!
Do not smoke when working on the fuel system or when refueling!
Before refuelling, stop the engine, raise the control lever base and remove the ignition key!
Do not refuel in closed rooms!
Wipe away fuel spills immediately!
Keep the machine clean to reduce the fire hazard!
Refueling
Filler inlet A for the fuel tank is located in the engine compartment, on the left in driving
direction.
Danger!
All work involving fuel carries an increased
Fire and poisoning hazard!
Do not refuel in closed rooms
Never perform work on the fuel system near open flames or sparks
No smoking, no fire!
Environment!
Use a suitable container to collect the fuel as it drains and dispose of it in an environmen-
tally friendly manner!
Notice!
Do not run the fuel tank completely dry. Otherwise, air is drawn into the fuel sys-
tem. This requires bleeding the fuel system – see Bleeding the fuel system on
page 5-4.
Notice!
Fill up the tank with the correct fuel type at the end of each working day. This pre-
vents condensation water from forming in the fuel tank over night. Do not fill the
tank completely but leave some space for the fuel to expand.
Abb. 180: Fuel filler inlet