BA 50Z3/6003 en – Edition 4.3 * 5003b520.fm 5-21
Maintenance
Indication
Temperature LED 1, alarm LED 5 and alarm symbol flash.
Error
No temperature change during the last 10 minutes.
Troubleshooting
Engine does not start.
Start the engine.
Absolutely constant engine load.
Replace the temperature sensor.
Contact an authorized workshop.
Indication
Temperature LED 1, alarm LED 6 and alarm symbol flash.
Error
Malfunctioning temperature sensor.
Troubleshooting
Replace the temperature sensor.
Contact an authorized workshop.
Indication
Pressure LED 8, alarm LED 1 and alarm symbol flash.
Error
Upper limit of exhaust gas counterpressure exceeded.
Troubleshooting
Immediately operate the machine in a way that puts a high load on the engine in order
to regenerate the filter. If the pressure does not fall after 5 minutes, stop the engine and
get in touch with an authorized workshop.
Indication
Alarm LED 3 and the alarm symbol flash.
Error
No engine speed signal from the alternator.
Troubleshooting
Wiring from controls to alternator.
Check the wiring.
Contact an authorized workshop.
Indication
Alarm LED 7 and the alarm symbol flash.
Error
Error during data recording.
Troubleshooting
Contact an authorized workshop.
12345678
Fig. 276: Error: no temperature change
12345678
Fig. 277: Error: malfunctioning temperature sensor
12345678
Fig. 278: Error: upper limit of exhaust gas counterpressure
exceeded
12345678
Fig. 279: Error: no engine speed signal from the alternator
12345678
Fig. 280: Error: data recording

Table of Contents