13 Technical data
100_0202_td_0018.fm 64
Maximum allowable hydraulic
pressure
bar 230 230
Coolant volume l 1.9 1.9
Type of coolant SAE J1034: water (1:1) SAE J1034: water (1:1)
Exciter oil quantity l 1.35 1.35
Type of exciter oil SAE 75W90 SAE 75W90
Hydraulic oil volume l 17.7 17.7
Type of hydraulic oil MR 520 MR 520
Storage temperature range °C 20 to +50 20 to +50
Operating temperature range °C 10 to +50 10 to +50
Sound pressure level
At location of operation L
pA
**
dB(A) 87 87
Standard EN 500-4
Sound power level L
wa
measured
guaranteed
dB(A)
108
109
108
109
Standard EN 500-4, 2000/14/EG
Vibration total value a
hv
m/s
2
00
Standard EN 500-4
Uncertainty of measurement
of the vibration total value a
hv
m/s
2
--
*
Dependent on soil conditions.
**
Measured at 5 m distance (remote controlled machine).
Designation Unit DPU 80rLe DPU 100rLe