BA D24 en/us* 1.0 * D24_1_0_700.fm 7-21
Maintenance 7
Emptying the water separator
Information
Empty the water separator, if error message SPN 97 appears in the
multifunctional display.
1. Stop the vehicle, stop the engine see "Preparing lubrication" on
page 7-6.
2. Place a suitable container under the water separator.
3. Open the engine cover.
4. Connect a suitable hose to the drain device A.
5. Disconnect electrical connection C.
6. Remove the vent screw D.
7. Open drain valve B.
8. Drain the fuel/water mixture into a receptacle.
9. Close drain valve B if nothing but fuel is flowing into the receptacle.
10.Tighten the vent screw D.
11.Connect electrical connection C.
12.Remove the hose.
13.Close and lock the engine cover.
Environment
Use a suitable container to collect fluids and lubricants as they flow out
and dispose of them in an environmentally friendly manner.
Fig. 163
D
B
A