BA EZ17 en* 1.1 * ez17w700.fm 7-35
Maintenance 7
Checking the coolant level
1. Stop and park the machine. Stop the engine. See “Preparing
lubrication”.
2. Check the coolant level on the sight glass.
3. If the coolant level is below the FULL mark:
➥ Add coolant.
Check the coolant level once a day before starting the engine.
Observe the coolant compound table
Adding coolant
1. Stop and park the machine. Stop the engine. See “Preparing
lubrication”.
2. Slacken screw B.
3. Remove cover A.
4. Carefully unscrew filler cap C and release the pressure.
5. Open filler cap C.
6. Top off the coolant up to the middle (FULL).
7. Close filler cap C.
8. Start the engine and let it warm up for about 5 – 10 minutes.
9. Stop the engine.
10.Remove the starting key and carry it with you.
11.Let the engine cool down.
12.Check the coolant level again.
13.If necessary, add coolant and repeat the procedure until the coolant
level remains constant.
14.Close and lock the engine cover.